Technical Guides

Installing Vacuum Glass: A Guide for Glaziers and Framers

Handling, framing and glazing guidance for VIG in new and existing frames — what glaziers and installers should know.

Ross Yudin, Managing Partner — THERM GLASS GROUP LLC
Share
Installing Vacuum Glass: A Guide for Glaziers and Framers

Vacuum insulated glass installs much like conventional glass, but its thin profile and sealed construction call for some specific practices. This guide covers what glaziers, framers and installers should know.

Handling and storage

  • Store units upright on padded A-frames, not flat
  • Protect the edges, since the edge seal is the most important part of the unit
  • Avoid hard impacts on corners and edges during handling
  • Don't use sharp tools near the edge seal

Choosing the frame

Glass is only part of a window's performance. To get the most out of VIG, use a thermally broken frame. THERMGLASS gives a whole-unit Uw of 0.73 W/m²·K in a thermally broken frame, calculated to ISO 10077-1. A conductive frame without a thermal break will lower whole-window performance.

Retrofits in existing frames

VIG's main advantage in retrofits is that it fits where triple glazing can't. At 6.3 to 10.3 mm, standalone units often fit original sashes and existing rebates. Before ordering:

  • Measure rebate depth and width at several points
  • Check the condition of the sash and repair any rot or damage
  • Confirm the sash can carry the weight of the new unit
  • In historic buildings, confirm requirements with the preservation authority

Setting and sealing

  • Use setting blocks at the correct points to support the unit's weight
  • Use glazing tapes and sealants that are compatible with the unit's edge
  • Don't clamp or point-load the unit
  • Follow the manufacturer's glazing details for your frame system

Curtain walls

THERMGLASS units are suited to lightweight curtain walls, including 4-sided structural silicone glazing. Work with the curtain wall engineer on structural silicone design and compatibility testing.

Hybrid units

Hybrid units combine VIG with an additional lite and cavity, for an overall depth of about 20.3 to 26 mm. Glaze them like a conventional IGU of the same depth.

Get the details

Glazing is done to the printed installation details issued for the specific unit type and frame system, not to general practice. Every THERMGLASS order ships with the printed installation instructions and glazing details for the specific unit type and frame system. Before ordering, request the current document set for your application — we will confirm which version applies to your project and supply it with the drawings.

Download the Technical Blueprint PDF, or send us a message for project-specific glazing details.

Keep reading

Two retrofit guides pair with this one: slim vacuum glass for old windows covers sash and frame preparation, and getting slim vacuum glass approved in historic districts covers the commission review. A completed four-season van install is in the camper van re-glaze.

Before panels reach site, handling matters: the glass care and handling guide covers lifting, storage, and edge protection from crate to sash.

Frequently Asked Questions

How should vacuum glass units be handled and stored?

Store units upright on padded A-frames rather than flat, and protect the edges — the edge seal is the most important part of the unit. Avoid hard impacts on corners and edges during handling, and keep sharp tools away from the seal.

Can vacuum glass be installed in existing sashes?

Often, yes: standalone units at 6.3–10.3 mm fit rebates cut for single-pane glass. Before ordering, measure rebate depth and width at several points, check the sash’s condition, confirm it can carry the new unit’s weight, and confirm requirements with the preservation authority in historic buildings.

What frame gives the best whole-window performance?

A thermally broken frame. THERMGLASS gives a whole-unit Uw of 0.73 W/m²·K in a thermally broken frame, calculated to ISO 10077-1 — a conductive frame without a thermal break lowers whole-window performance.

Related guides

All Technical Guides

Run your project numbers.

Use the THERMGLASS ROI engines to calculate energy payback for your specific application.

Open the configurators