Field Guide

Glass Care and Handling for Vacuum Insulating Glass

Edge protection, safe transport and installation practice, and cleaning recommendations for VIG units - summarized from the THERMGLASS field guide.

Every vacuum insulating glass unit is sealed at the factory: two lites of glass joined around the full perimeter by a welded edge seal, with the cavity between them evacuated and closed at manufacture. That edge seal is the vacuum boundary - and the most vulnerable part of the unit in the field.

A chip, crack, or hard impact that reaches the seal can breach the vacuum. A VIG unit that loses its vacuum cannot be re-evacuated on site - it is replaced, not repaired. The practices below protect the edge, keep point loads off the glass, and keep incompatible chemistries away from the seal.

Receiving and inspection

Inspect at delivery, before the carrier leaves - what you sign for is what you accepted.

A unit with visible edge damage does not go into a frame. Quarantine it, document it, and contact THERMGLASS before proceeding with the surrounding work.

  • Inspect the packaging before signing; note any crush damage, broken strapping, or a shifted load on the delivery receipt.
  • Confirm edge and corner protection is present on every unit - all four edges, not just the visible ones.
  • Inspect each unit in daylight: both faces and all four edges. Look for chips, cracks, scratches, and seal-surface damage.
  • Photograph any damage before signing, then quarantine the affected units. Do not install them.
  • Check quantity, size, and configuration against the packing list before the carrier departs.

Storage

Glass is strongest in its plane and most at risk across its edges. Storage position follows from that.

  • Store units vertical or near-vertical on A-frames or padded racks, with a slight backward lean onto clean, dry padded rails.
  • Keep the factory edge and corner protection in place until the unit goes into the frame.
  • Rack contacts should bear on the glass faces through clean padding - never directly on the edge seal, and never on bare concrete or steel.
  • Never stack units in direct edge-to-edge contact; separate every unit with dry, clean interleaving.
  • Store indoors or under cover, off the ground, away from standing water and roof runoff.
  • Keep units clear of hot work: weld spatter and grinding sparks permanently mark glass surfaces.
  • Do not rest tools, materials, or ladders against stored units.

Transport and handling

Most VIG units are light for their size, but their edges do not forgive shortcuts.

If a unit is dropped - even a short distance and even if it looks fine - set it aside and inspect the full perimeter before it moves again. Edge damage is not always visible from a standing position.

  • Transport and move units vertical or near-vertical, in the packing format the fabricator specifies.
  • Pad every strap and every contact point; never let a bare strap, chain, or unlabeled hook touch glass.
  • Never slide or drag a unit on its edge. Lift and set - do not shuffle.
  • Lift with suction lifters placed on the glass faces, or carry with two people. Suction cups never grip the edge zone.
  • Do not carry a large unit flat, held only at opposite edges; flexing plus a corner strike is how units break.
  • Set units down on padded rails or edge-protected blocks - never onto a bare corner or edge.
  • Keep factory protection on through every move; it is cheaper than any unit it protects.

Frame preparation

The frame decides how the unit is loaded for its whole service life. Prepare it that way.

  • Confirm the opening is clean, square, and free of debris, weld spatter, and cured sealant remnants.
  • Verify channel depth, clearance, and block positions against the fabricator drawings for the unit and frame combination being glazed.
  • Clean the setting-block bearing surfaces; debris under a block is a point load on the glass.

Setting blocks and support

  • Support the unit on setting blocks exactly where the fabricator drawings show them. Do not improvise block positions that load the edge seal unevenly.
  • The unit must never bear directly on frame metal, fasteners, or an uneven bed; the blocks are the only contact.
  • Location blocks position the unit edge-to-edge but should not preload it - a wedged-in unit is a unit under stress.

Gaskets, sealants, and compatibility

  • Use neutral-cure silicone or gasket systems confirmed compatible with sealed-unit edge seals.
  • Keep acetic-cure silicones, solvent-based sealants, and unverified chemistries away from the edge seal; solvent attack on seal materials is a recognized failure mode in sealed-unit glazing.
  • Do not allow sealants or cleaners to pool or soak against the edge seal; tool and wipe promptly.

Installation hard rules

If site conditions force a departure from the drawings - an out-of-square opening, a substitute gasket, a modified reveal - stop and confirm with THERMGLASS before glazing. A five-minute question is cheaper than a replaced unit.

  • Never cut, drill, notch, or edge-grind a VIG unit. The edge seal is manufactured geometry - reworking it destroys the unit.
  • Never use the glass as a work platform, step, or tool rest; never rest anything on the edge.
  • Maintain weep and drainage paths so the edge seal does not stand in water.
  • Glaze per the fabricator glazing instructions. Where those instructions differ from this guide, the fabricator instructions govern.

Cleaning and maintenance

Clean the glass faces the way you would clean any quality glazing: gently, with clean tools, and with an eye on the edges.

Inspect the edge seal visually as part of routine maintenance; look for chips, cracks, or seal-surface damage and report anything new.

  • Routine cleaning: soft microfiber cloth or clean squeegee with mild soap and water, or a standard non-abrasive glass cleaner.
  • Rinse with clean water and dry with a clean cloth; do not let cleaning solutions dry on the glass.
  • Avoid abrasive pads, abrasive powders and creams, and scrapers or razor blades, especially on coated faces.
  • Do not aim pressure-washer jets at glass edges, frame joints, or seals; high-pressure water finds its way past seals.
  • Use solvents sparingly for spot work such as labels and adhesives, wipe promptly, and never let them soak or pool against the edge seal.
  • Lift construction debris such as mortar spatter and paint by soaking and gentle lifting - never scrape aggressively toward an edge.

Frequently asked questions

Can a damaged vacuum glass unit be repaired in the field?

No. The vacuum is sealed at the factory and cannot be re-evacuated on site. A unit with edge damage or a breached seal is replaced, not repaired - document the damage, quarantine the unit, and contact THERMGLASS.

Can I pressure-wash vacuum insulating glass?

Keep pressure-washer jets away from glass edges, frame joints, and seals - high-pressure water finds its way past seals. Clean faces with mild soap and water or a standard non-abrasive glass cleaner and a soft cloth instead.

Which sealants and gaskets are safe near the edge seal?

Use neutral-cure silicone or gasket systems confirmed compatible with sealed-unit edge seals. Keep acetic-cure silicones and solvent-based sealants away from the edge - solvent attack on seal materials is a recognized failure mode in sealed-unit glazing.

How should VIG units be stored on site?

Vertical or near-vertical on A-frames or padded racks with a slight backward lean onto clean, dry padded rails, with factory edge and corner protection in place until the unit is glazed.

Download the printable field guide

The four-page PDF version of this guide - with the quick-reference DO / AVOID table - is available as a gated download from the technical resource center. A free trade account is required.