Every output value in the THERMGLASS configurator suite is derived from published engineering standards. This page documents the calculation methods, input assumptions, boundary conditions, and known limitations for each tool.

The five THERMGLASS configurators are specification-assistance tools, not certified rating instruments. Outputs are indicative values derived from published standards and should be verified by independent testing before use in permit submissions, procurement contracts, or certified energy models.

US Thermal Performance (Btu/h·ft²·°F)

VIG & Hybrid Configurator · Cold Storage Configurator

EU/UK Thermal Performance (W/m²·K)

EU Architectural Configurator · EU Cold Storage Configurator

Marine Thermal Performance (W/m²·K)

Marine Configurator

Condensation Resistance

All five configurators

Acoustic Performance

All five configurators

Code Compliance Thresholds

All five configurators

Optical Properties (VLT & SHGC)

VIG & Hybrid Configurator

Indicative Pricing

All five configurators

Analysis Reports

Mathematical Validation Documents

Full derivations, formula references, and boundary condition documentation for all five THERMGLASS configurators. All configurator outputs have been verified against these source documents.

Branded reports included. Each download is a fully branded THERMGLASS document — a custom cover page with your logo, thermal gradient design, applicable standards, and document metadata is automatically prepended to every report.

THERMGLASS
TECHNICAL ANALYSIS

US ARCHITECTURAL & COMMERCIAL

VIG Mathematical Analysis

IECC 2021ASHRAE 90.1NFRC 500LEED v4
TGG-VIG-US-001thermglass.com

US Architectural & Commercial

VIG Mathematical Analysis

COG U-factor derivation (IP units), whole-window area-weighted method, IECC 2021, ENERGY STAR v7, PHI, LEED v4, ASHRAE 90.1-2022. Condensation resistance (NFRC 500 proxy), R-value, VLT, SHGC.

Includes THERMGLASS branded cover page
Loading preview…
THERMGLASS
TECHNICAL ANALYSIS

EU / UK ARCHITECTURAL & COMMERCIAL

VIG EU & UK Analysis

EN 673EN ISO 10077-1EPBDBREEAM
TGG-VIG-EU-001thermglass.com

EU / UK Architectural & Commercial

VIG EU & UK Analysis

EN 673 COG U-value (SI units), EN 10077-1 whole-window Uw, EPBD nZEB by climate region, PHI, EnerPHit, England Part L 2021, BREEAM Mat 05. EN ISO 13788 fRsi condensation factor.

Includes THERMGLASS branded cover page
Loading preview…
THERMGLASS
TECHNICAL ANALYSIS

COLD STORAGE & REFRIGERATION

Cold Storage VIG Analysis

NSF/ANSI 7ASHRAE 90.1ITO Anti-FogMagnus DP
TGG-CS-US-001thermglass.com

Cold Storage & Refrigeration

Cold Storage VIG Analysis

Dew point calculation (Alduchov & Eskridge), ITO anti-fog coating, NSF/ANSI 7 compliance, ASHRAE 90.1-2022, NFRC 500 condensation resistance proxy. 10 application types from display cases to blast-freeze.

Includes THERMGLASS branded cover page
Loading preview…
THERMGLASS
TECHNICAL ANALYSIS

EU / UK COLD STORAGE & REFRIGERATION

VIG EU & UK Cold Storage Analysis

EN 673EN ISO 23953EN 1672-2BREEAM
TGG-CS-EU-001thermglass.com

EU / UK Cold Storage & Refrigeration

VIG EU & UK Cold Storage Analysis

EN 673 COG U-value (SI units), EN 10077-1 whole-unit Uw, Magnus dew point, EN ISO 23953 cabinet performance, BREEAM, EN 1672-2 hygienic frame, blast freeze advisory (ΔT ≥ 60 K).

Includes THERMGLASS branded cover page
Loading preview…
THERMGLASS
TECHNICAL ANALYSIS

MARINE & OFFSHORE

Marine VIG Product Specification Matrix

ISO 10077-1EN 673IMO A.1116(30)DNV
TGG-MAR-001thermglass.com

Marine & Offshore

Marine VIG Product Specification Matrix

ISO 10077-1 whole-unit Uw, EN 673 COG U-value, salt-spray corrosion resistance by frame material, IMO Resolution A.1116(30) fire-rated glazing advisory, DNV type approval guidance, and USD pricing with marine-premium edge seal.

Includes THERMGLASS branded cover page
Loading preview…

Important Disclaimer

All configurator outputs are indicative values derived from published engineering standards and internal THERMGLASS product data. They are not certified ratings and should not be used in permit submissions, procurement contracts, or certified energy models without independent verification. THERMGLASS accepts no liability for decisions made solely on the basis of configurator outputs. Contact THERMGLASS for project-specific engineering support.

Ready to spec your project?