Superyacht on open ocean — EU/UK marine glazing

Markets · EU/UK Marine

EU/UK Marine & Offshore Glazing

EN ISO 10077-1 whole-unit U-values, Rw 38–42 dB acoustics, and IMO fire-rated glazing advisory for EU/UK-flagged superyachts, passenger ferries, offshore platforms, and commercial vessels. EUR pricing.

Performance basis: COG U-values calculated per EN 673; whole-unit Uw calculated per EN ISO 10077-1; Rw per EN ISO 717-1 — calculated values, not laboratory test data. Classification type approval (DNV, Lloyd's Register, Bureau Veritas, RINA, MCA) is in progress.

EU & UK Marine Applications

Built for EU/UK Classification and the Harshest Marine Environments

THERMGLASS VIG delivers EN 673 center-of-glass U-values of 0.46 W/m²K (standalone) and 0.22 W/m²K (hybrid) with standalone units from 6.3 mm (3 mm lites) to 10.3 mm (5 mm lites) overall, and hybrid builds at ≈20.3–26 mm — engineered for salt-spray corrosion resistance, structural vibration, and the extreme thermal differentials of Arctic and tropical operating regions.

Marine-premium edge seal supports DNV, Lloyd's Register, Bureau Veritas, RINA, and MCA classification documentation. IMO fire-rated glazing advisory is integrated into the EU Marine Configurator — actual compliance requires type-approved, FTP Code-tested glazing certified by an accredited laboratory. EU Directive 2009/45/EC passenger vessel requirements are flagged automatically.

0.46 W/m²K

COG U-Value (Standalone)

0.22 W/m²K

COG U-Value (Hybrid)

6.3–10.3 mm standalone · ≈20.3–26 mm hybrid

Profile Thickness

38–42 dB

Acoustic (Rw, approx.)

~50% lighter than a 24 mm triple-pane (4 mm lites) · ≈ same glass weight as dual-pane

Weight vs. Reference IGUs

EN ISO 10077-1, EN 673 — class-society documentation support in progress

Standards Basis

Applications

Where THERMGLASS Performs

Superyachts & Luxury Vessels

Ultra-slim standalone units — 6.3 mm with 3 mm lites, up to 10.3 mm with 5 mm lites — fit bespoke frame systems without structural redesign. Approximate Rw 38 dB (standalone) to Rw 42 dB (laminated or hybrid) acoustic performance reduces engine and sea-state noise in saloons, staterooms, and wheelhouses. EUR pricing with marine-premium edge seal.

EU/UK Passenger Ferries & RoPax

Whole-unit Uw values calculated to EN ISO 10077-1 support HVAC load reduction and EU Directive 2009/45/EC documentation. Reduced glazing U-value lowers heating and cooling demand across large glazed areas on short-sea and cross-channel routes.

North Sea Offshore Platforms & Workboats

Hybrid VIG makeup rated for ΔT extremes in North Sea and Arctic operating regions. Polar Code thermal advisory built into the EU Marine Configurator flags MSC.385(94) compliance requirements automatically for vessels on polar routes.

Naval & Coast Guard Vessels

Structural integrity under vibration and dynamic loading. IMO fire-rated glazing toggle in the EU Marine Configurator outputs a compliance advisory for vessels subject to SOLAS Chapter II-2 requirements — actual fire-rated glazing must be type-approved and FTP Code tested.

Key Benefits

EU/UK Marine-Grade Performance Advantages

EN ISO 10077-1 Whole-Unit U-Values

Area-weighted Uw calculation per EN ISO 10077-1 — standalone 0.46 W/m²K COG; hybrid 0.22 W/m²K COG. Actual frame area ratio varies by glazing type and vessel design. EN 673 COG U-values; ISO 19916-1 referenced for VIG-specific thermal assessment.

Marine-Premium Edge Seal

Enhanced corrosion-resistant edge seal rated for continuous salt-spray exposure. EUR adder pricing built into the EU Marine Configurator: €300/m² standalone, €700/m² hybrid.

Rw 38–42 dB Acoustic Performance

EN ISO 717-1 rated acoustic attenuation. Standalone VIG achieves approximately Rw 38 dB; the upper range (Rw 42 dB) requires a laminated or hybrid build. Reduces engine noise, sea-state impact, and port ambient noise in occupied spaces.

Weight Reduction vs. 24 mm Triple-Pane

Monolithic VIG (6.3 mm unit with 3 mm lites) is approximately 50% lighter than a conventional 24 mm triple-pane IGU of equivalent glass area. Glass weight is roughly the same as the dual-pane IGUs most vessels already have — the ~50% saving applies specifically against 24 mm triple-pane builds with 4 mm lites. Weight advantage narrows for hybrid builds (up to ≈26 mm overall profile). Improves vessel stability, fuel efficiency, and structural load margins.

Polar Code & Arctic Compliance

Hybrid VIG makeup recommended for operating regions with ΔT ≥ 40 K. The EU Marine Configurator outputs a Polar Code thermal advisory for Arctic and global-trading routes per MSC.385(94) automatically.

DNV, LR, BV, RINA & MCA Documentation

Performance data formatted to support EU and UK classification society energy assessments. EN ISO 10077-1 Uw values, EN 673 COG U-values, and marine-premium edge seal documentation available on request. Type approval in progress.

Technical Reading

From the THERMGLASS Technical Blog

Calculator Guide

Energy Savings Calculator Guide: Accurate Results for VIG Projects

How to use THERMGLASS's six ROI engines correctly — input assumptions, fuel type selection, climate zone data, and interpreting NPV outputs for VIG projects.

Read the guide
Technical Comparison

Thermal Insulation Comparison: VIG vs. Triple Glazing vs. Low-E IGU

Side-by-side analysis of U-values, SHGC, weight, and thickness across glazing types — with data grounded in EN 673 and NFRC 100 test standards.

Read the guide
ROI & Energy Analysis

VIG Glazing ROI: How to Calculate Real Energy Payback

A step-by-step methodology for calculating NPV, payback period, and annual energy savings from VIG upgrades using U-value differentials and ASHRAE steady-state models.

Read the guide

Specify THERMGLASS for Your EU/UK Vessel

Use the EU Marine Configurator to model EN ISO 10077-1 U-values, Rw acoustic performance, Polar Code compliance, and EUR pricing with marine-premium edge seal — then contact us for a sample or full specification package.