Commercial refrigeration display cases

Markets · Refrigeration

Clear doors without heater wiring

Warm-edge vacuum insulating glass keeps cooler and freezer door glass above the dew point — so anti-sweat heaters can be reduced or removed while door heat gain drops 71–91% versus double-pane.

Design basis: no visible condensation at NSF/ANSI 7 Class 0 test conditions — 90°F dry-bulb / 80°F wet-bulb ambient, case at +38°F. Class 0 certification is issued to the completed OEM cabinet.

The Cold Chain Problem

Glass doors: one of the largest heat loads in a display case

In glass-door merchandisers, conduction through the door glass is one of the largest sources of heat gain in glass-door cases — though in walk-ins, air exchange through door openings is often larger, and the balance varies by case type. Conventional double-pane IGU doors in coolers, freezers, and display cases still operate at or below the dew point of ambient store air — driving continuous condensation, anti-sweat heater energy draw, and compressor overload. THERMGLASS Warm-Edge VIG is designed to remove that failure mode in standard ambient conditions.

With a center-of-glass U-factor as low as 0.025 Btu/h·ft²·°F and Condensation Resistance ratings of 77–94, THERMGLASS cold storage glass doors are designed to keep interior surface temperatures above the dew point in standard ambient conditions without resistive heating — cutting energy consumption 71–91% versus a reference double-pane IGU. Engineered to support NSF/ANSI 7 OEM cabinet compliance for commercial refrigerators and freezers.

Industrial cold storage freezer room with refrigerated shelving

Applications

Where THERMGLASS Performs

Walk-In Coolers & Freezers

Positive-temperature coolers (+32°F to +41°F) and sub-zero freezers (-10°F to 0°F). THERMGLASS Standalone VIG handles cooler doors; Hybrid VIG is specified for freezer applications requiring CR 85+ and whole-unit U-factors below 0.10 Btu/h·ft²·°F.

Refrigerated Display Cases

Glass-door reach-in and open-front display cases for supermarkets, convenience stores, and food service. Anti-sweat heater wiring can be eliminated at typical store ambient conditions, reducing compressor cycling and improving product visibility with glass surfaces kept above the dew point — ITO-coated heated glass is available for high-humidity environments.

Glass Door Freezer Cases

Low-temperature glass door freezer cases (-10°F to -20°F) for ice cream, frozen meals, and frozen beverages. Hybrid VIG with ITO-coated anti-fog heated glass option for extreme dew point differentials in high-humidity store environments.

Blast Freeze Chambers & Cold Chain

Extreme low-temperature blast freeze chambers (-20°F to -40°F) and refrigerated warehouse vision panels. Maximum R-value Hybrid VIG with heated gasket systems. Supports NSF/ANSI 7 OEM cabinet compliance. Suitable for pharmaceutical cold chain, food processing, and industrial cold storage.

Key Benefits

Cold Storage Performance Advantages

71–91% Energy Savings vs. Reference IGU

Conductive heat gain through the glass door is a dominant energy load in refrigerated display cases. THERMGLASS VIG reduces that load by 71–91% compared to a standard double-pane IGU, cutting compressor runtime and lowering utility costs across the entire cold chain.

Glass Kept Above the Dew Point — Heaters Reduced or Removed

Condensation Resistance ratings of 77–94 are designed to keep glass surface temperatures above the ambient dew point across standard operating conditions — no visible condensation at NSF/ANSI 7 Class 0 test conditions. Anti-sweat heater wiring can be reduced or removed, cutting electrical load and removing the maintenance liability of failed heater elements in door frames. For extreme dew point differentials, an ITO-coated heated glass option is available.

Supports NSF/ANSI 7 OEM Cabinet Compliance

THERMGLASS VIG is engineered to support OEM cabinet compliance with NSF/ANSI 7 temperature-retention and sanitation requirements. Whole-unit U-factors of 0.039–0.081 Btu/h·ft²·°F are well below the 0.35 Btu/h·ft²·°F engineering threshold derived from NSF/ANSI 7 §7 performance requirements. NSF/ANSI 7 certification is issued to the completed OEM cabinet — not to individual glass components.

Slim Profiles — Retrofit-Ready

Standalone VIG profiles from 6.3mm fit existing door frame rebates designed for standard double-pane IGU. Retrofit walk-in cooler and display case doors without frame replacement — a direct drop-in upgrade that delivers vacuum-grade thermal performance.

Technical Reading

From the THERMGLASS Technical Blog

Cold Storage

Vacuum Glass for Supermarket Refrigeration Doors

Vacuum glass cuts display-door heat gain and takes anti-sweat heaters out of the loop — door U-values and heater watts, per ASHRAE Refrigeration 2022.

Read the guide
Cold Storage

Cold Storage Efficiency: The Hidden Cost of Poor Door Glazing

Quantifying compressor energy waste from high-U glass in walk-in coolers and freezers using ASHRAE Refrigeration 2022 §14 load models — with real payback calculations.

Read the guide
ROI & Energy Analysis

VIG Glazing ROI: How to Calculate Real Energy Payback

A step-by-step methodology for calculating NPV, payback period, and annual energy savings from VIG upgrades using U-value differentials and ASHRAE steady-state models.

Read the guide

Compliance Data

NSF/ANSI 7 & ASHRAE 90.1 Compliance Data

THERMGLASS VIG is engineered to support OEM cabinet compliance with NSF/ANSI 7 Class 0 heavy condensation test requirements and ASHRAE 90.1-2022 commercial refrigeration energy efficiency standards. The following data reflects design-intent performance parameters for the THERMGLASS cold storage product line.

NSF/ANSI 7 Class 0 Heavy Condensation Test

Pass (design intent)

NSF/ANSI 7 Class 0 is the most demanding condensation classification — requiring no visible condensation on glass surfaces at 90°F (32°C) dry-bulb / 80°F (27°C) wet-bulb ambient conditions with cabinet interior at +38°F (+3°C). THERMGLASS Standalone VIG (CR 77+) and Hybrid VIG (CR 90+) are designed to maintain interior glass surface temperatures above the ambient dew point — about 77°F (25°C) at the Class 0 design condition of 90°F dry-bulb / 80°F wet-bulb — without anti-sweat heaters. Class 0 certification is issued to the completed OEM cabinet assembly — THERMGLASS VIG supports OEM compliance; it does not independently hold NSF/ANSI 7 Class 0 certification.

Cabinet Pull-Down Energy Reduction

71–91% vs. reference double-pane IGU

Cabinet pull-down energy reduction is calculated relative to a reference clear air-filled double-pane IGU (COG U-factor 0.28 Btu/h·ft²·°F / 1.59 W/m²·K). THERMGLASS Standalone VIG (0.081 Btu/h·ft²·°F) reduces conductive heat gain by 71%; Hybrid VIG (0.039 Btu/h·ft²·°F) reduces it by 86%. Eliminating anti-sweat heater wiring (typically 7–12 W per linear foot of door perimeter) provides an additional 15–25% reduction in total door energy consumption, bringing combined savings to 71–91% depending on application type and ambient conditions.

ASHRAE 90.1-2022 Commercial Refrigeration Compliance

Compliant — exceeds maximum U-factor thresholds

ASHRAE 90.1-2022 §6.4.3 sets maximum whole-unit U-factors for refrigerated case doors: 0.25 Btu/h·ft²·°F for refrigerated display case doors and 0.30 Btu/h·ft²·°F for walk-in cooler/freezer doors. THERMGLASS VIG whole-unit U-factors (including frame, per NFRC 100 area-weighted methodology) range from 0.068 Btu/h·ft²·°F (Standalone VIG, aluminium frame) to 0.034 Btu/h·ft²·°F (Hybrid VIG, aluminium frame) — exceeding both ASHRAE 90.1-2022 thresholds by a factor of 3–7×. DOE commercial refrigeration equipment standards (10 CFR Part 431) require ≤0.30 Btu/h·ft²·°F; THERMGLASS VIG exceeds this threshold across all standard makeups.

Anti-Sweat Heater Elimination — ASHRAE 90.1 §6.4.3.4

Heater wiring not required

ASHRAE 90.1-2022 §6.4.3.4 requires that anti-sweat heaters on refrigerated case doors be controlled by a humidity sensor or be rated at ≤7.1 W/linear foot of door perimeter. THERMGLASS VIG can remove the anti-sweat heater requirement in standard ambient conditions — achieving condensation-free performance through thermal performance alone (CR 77–94). This removes the §6.4.3.4 compliance burden from the OEM cabinet design and eliminates the associated electrical load from the facility's energy model.

All compliance data reflects design-intent performance parameters. NSF/ANSI 7 certification is issued to completed OEM cabinet assemblies — not to individual glass components. ASHRAE 90.1 compliance requires certified NFRC 100 whole-window U-factor testing for the specific product and installation. Contact THERMGLASS for project-specific engineering documentation.

Cold Storage Configurator

Spec your cooler or freezer glazing

Select your application type, temperature zone, and frame system — get a recommended THERMGLASS makeup, U-factor, condensation resistance rating, and ASHRAE 90.1 compliance check.

Specify THERMGLASS for your cold storage project

Use the Cold Storage Configurator to select your application type, temperature zone, and frame system — get a recommended glass makeup, U-factor, condensation resistance rating, and ASHRAE 90.1 compliance check instantly.

FAQ

Frequently Asked Questions

THERMGLASS Standalone VIG is the optimal glass for walk-in cooler doors. With a COG U-factor of 0.081 Btu/h·ft²·°F and Condensation Resistance of 77+, it maintains surface temperatures above the dew point at typical cooler operating conditions (+35°F to +38°F interior) without anti-sweat heater wiring. Profiles from 6.3mm fit existing door frame rebates as a direct retrofit.