Specifying Vacuum Insulated Glass: A CSI MasterFormat Guide for Architects

How to write vacuum insulated glass into a project specification — the right MasterFormat section, the performance attributes to call out, substitution clause language, and the NBS equivalent for UK projects.

Ross Yudin, Managing Partner — THERM GLASS GROUP LLC
Share
Specifying Vacuum Insulated Glass: A CSI MasterFormat Guide for Architects

Vacuum insulated glass is a relatively new product category, and most office specification libraries do not have a master section for it yet. That creates a practical problem: a specifier who wants to call out VIG has to decide where it lives in the document hierarchy, what performance attributes to require, and how to write substitution language that keeps the project open to competition without accepting a product that cannot meet the thermal brief.

This post works through each of those decisions for US projects using CSI MasterFormat, with a parallel note for UK projects using NBS. It is not a substitute for a project-specific specification review by a licensed architect or specification consultant — it is a starting point for offices that have not written VIG before and want to understand the structure before they draft.

Where VIG lives in CSI MasterFormat

CSI MasterFormat organizes building products into numbered divisions. Glazing products sit in Division 08 — Openings, and the relevant sections are:

  • 08 80 00 Glazing — the parent section for all glazing products and systems
  • 08 81 00 Glass Glazing — monolithic and laminated glass
  • 08 83 00 Mirrors — not relevant here
  • 08 88 00 Special Function Glazing — the section most commonly used for high-performance and specialty glazing products

For a standalone VIG unit specified as a glazing product (supplied to the glazing contractor for installation into an existing or new frame), 08 88 00 Special Function Glazing is the most defensible home. Some offices file it under 08 81 13 Flat Glass when the VIG unit is being treated as a direct replacement for a conventional IGU in a window or curtain wall system; either is workable provided the section scope statement is clear.

For a complete window unit where the VIG is factory-glazed into a frame and supplied as a finished assembly, the specification typically lives in the window section — 08 51 13 Aluminum Windows, 08 52 00 Wood Windows, or the relevant curtain wall section — with the glazing performance called out as a product attribute of the window assembly rather than a separate glazing section.

The performance attributes to specify

A well-written glazing specification calls out performance, not brand. The attributes that define a vacuum insulated glass unit and distinguish it from conventional alternatives are:

Thermal performance

Center-of-glass U-factor: The primary thermal metric. For a standalone THERMGLASS VIG unit, the center-of-glass U-factor is 0.46 W/m²·K (0.081 Btu/h·ft²·°F) in the standard build. For a hybrid assembly (VIG panel bonded to a conventional IGU cavity), it is approximately 0.25 W/m²·K (0.044 Btu/h·ft²·°F). These figures are calculation-derived under EN 673 / ISO 10292 conditions; NFRC 100/500 and EN 673 type-approval testing is in progress, and ISO 19916-1 is the primary standard governing the vacuum-gap construction. Specify the center-of-glass U-factor as a maximum, not a target, and require the basis of calculation or test report to be submitted with the product data.

Whole-window U-factor: For energy code compliance, the number that matters is the whole-window U-factor, which blends the glass and frame under ISO 10077-1 (or NFRC 100 for US projects). A standard 6.3 mm VIG unit in a typical aluminum frame lands near 0.73 W/m²·K whole-window; the hybrid build in the same frame is approximately 0.47 W/m²·K. Specify the whole-window U-factor where energy code compliance is the driver, and require an NFRC-certified simulation or test report.

Solar Heat Gain Coefficient (SHGC): Specify as a maximum for cooling-dominated climates or facades with significant solar exposure, and as a minimum where passive solar gain is part of the heating strategy. The standard THERMGLASS build with its integral low-E coating has an SHGC near 0.62; the coating library spans approximately 0.22–0.74 depending on configuration. Require the SHGC to be reported alongside the U-factor in product submittals.

Physical construction

Overall unit thickness: Specify the maximum and minimum acceptable unit depth for the rebate. A standalone VIG unit is 6.3 mm (two 3 mm lites), 8.3 mm (two 4 mm lites), or 10.3 mm (two 5 mm lites) — the overall depth equals the glass stack because the frit edge seal is flush with the glass faces. A hybrid unit runs 20.3–26 mm overall. Calling out the maximum depth protects the frame detail; calling out the minimum prevents substitution of a thinner product that cannot meet the thermal requirement.

Edge seal type: Specify a fused glass-frit perimeter seal, portless construction. This distinguishes vacuum glass from products that use a metallic or polymer edge seal and a pump-out port, which add perimeter build-up and introduce a different long-term seal durability profile. The frit seal is what allows the unit depth to equal the glass stack exactly.

Vacuum gap pressure: Specify evacuation to below 0.1 Pa. This is the threshold at which gas conduction becomes negligible and the unit's thermal performance is governed by radiation rather than conduction. Products that do not reach this pressure level will not deliver the center-of-glass U-factor the specification requires.

Support pillar construction: Specify a micro-pillar support grid across the vacuum gap. The pillars hold the lites apart against atmospheric pressure; their spacing, diameter, and material affect both the structural performance of the unit and the visible appearance of the glass. Require the pillar specification to be included in product data submittals.

Durability and warranty

Warranty term: Specify a minimum warranty period for the vacuum seal — 15 years is the current THERMGLASS standard. Require the warranty to cover loss of vacuum (evidenced by fogging or condensation between the lites) as a product defect, not a consequential damage exclusion.

Governing standard: Specify ISO 19916-1 as the governing standard for vacuum insulating glass unit construction and performance. This is the international standard that defines the product category, the test methods, and the performance requirements. Requiring compliance with ISO 19916-1 in the specification gives the substitution review a clear technical basis.

Substitution clause language

Substitution clauses are where specifications either protect the design intent or inadvertently open the door to products that cannot meet it. For VIG, the risk is substitution with a conventional high-performance IGU that meets the whole-window U-factor on paper but does so in a unit depth that does not fit the frame detail, or that requires a frame modification that changes the facade appearance.

The following language is a starting-point draft — review with your specification consultant and legal counsel before use:

Substitutions: Requests for substitution of the specified vacuum insulated glass product will be considered provided the proposed product demonstrates: (1) center-of-glass U-factor not exceeding [X] W/m²·K ([Y] Btu/h·ft²·°F) by calculation or test under EN 673 / ISO 10292 or NFRC 100; (2) overall unit depth not exceeding [Z] mm; (3) fused glass-frit perimeter seal, portless construction; (4) vacuum gap evacuated to below 0.1 Pa; (5) compliance with ISO 19916-1; and (6) minimum 15-year warranty covering loss of vacuum. Substitution requests that do not address all six criteria will not be reviewed.

The depth criterion (item 2) is the most important for retrofit and historic district projects, where the frame rebate is fixed. A conventional triple-pane unit that meets the U-factor requirement at 28–44 mm overall depth is not a valid substitution for a 6.3 mm VIG unit in a rebate cut for single-pane glass — but without an explicit depth criterion in the substitution clause, that argument is harder to make.

Coordination with other sections

A glazing specification does not stand alone. The sections that need to be coordinated with the VIG spec include:

08 44 00 Curtain Wall and Glazed Assemblies — if the VIG unit is being installed in a curtain wall system, the curtain wall section needs to call out the glazing pocket depth and the setting block specification compatible with the VIG unit's edge construction. The flush frit seal means the unit sits differently in the pocket than a conventional IGU with a raised spacer bar.

07 92 00 Joint Sealants — the perimeter sealant at the glazing rebate needs to be compatible with the frit seal material. Require the VIG manufacturer's approved sealant list to be submitted with product data, and coordinate with the sealant section.

01 25 00 Substitution Procedures — the project's general substitution procedure section governs the process; the glazing section's substitution language defines the technical criteria. Both need to be consistent.

01 33 00 Submittal Procedures — require product data, shop drawings, and test reports as submittals. For VIG, the critical submittal is the calculation or test report supporting the center-of-glass U-factor and SHGC claims, and the ISO 19916-1 compliance documentation.

NBS equivalents for UK projects

UK projects using the National Building Specification (NBS) follow a different numbering system, but the product category logic is the same. Vacuum insulated glass sits within the L work section group (Windows, Doors, and Stairs) or the H group (Cladding and Covering) depending on whether it is specified as a glazing product or as part of a curtain wall assembly.

The most relevant NBS work sections are:

  • L40 General glazing — for VIG specified as a glazing product supplied to the glazing contractor
  • H11 Curtain walling — for VIG specified as part of a curtain wall assembly
  • L10 Windows / Rooflights / Screens / Louvres — for complete window units factory-glazed with VIG

Within an NBS L40 section, the performance attributes to specify are the same as the CSI equivalents: center-of-glass U-value (W/m²·K), whole-window U-value under ISO 10077-1, SHGC (or g-value in UK/EU notation), overall unit depth, edge seal type, vacuum gap pressure, and warranty term. The governing standard is the same: ISO 19916-1.

For UK energy compliance, the relevant performance target is set by Part L of the Building Regulations (England) or the equivalent devolved regulations, and the whole-window U-value is assessed against the notional building specification in the National Calculation Methodology. The THERMGLASS EU Architectural Configurator outputs values in W/m²·K and reports the whole-window U-value under ISO 10077-1, which is the calculation method accepted for Part L compliance.

What to include in the submittal package

A complete VIG product submittal for a specification review should include:

  1. Product data sheet — unit construction (lite thicknesses, gap dimension, edge seal type), available sizes, weight per square meter, and the standard range of builds
  2. Thermal performance calculation — center-of-glass U-factor and SHGC for the specified configuration, with the calculation method and standard cited (EN 673 / ISO 10292 or NFRC 100/200)
  3. Whole-window simulation — ISO 10077-1 or NFRC 100 whole-window U-factor for the specified frame and glazing combination
  4. ISO 19916-1 compliance documentation — the standard's requirements for vacuum insulating glass units, and how the product meets them
  5. Warranty document — the full warranty text, including the coverage period, what constitutes a covered defect (loss of vacuum), and the remedy
  6. Installation guide — setting block specification, edge clearance requirements, approved sealants, and handling requirements

For projects where acoustic performance is also specified, add the STC or Rw test report (or design-stage estimate with its basis stated) to the submittal package. For projects with BREEAM V7 credits in scope, the thermal performance data feeds directly into the Mat 05 (Design for Durability and Resilience) and Ene 02 (Energy Monitoring) credit calculations — coordinate with the BREEAM assessor on the required evidence format.

For projects targeting PHI or PHIUS Passive House certification, the same submittal package feeds the PHPP or WUFI Passive window worksheet directly — Uw, g-value, and ψ-install are the four inputs the energy balance requires. See PHI vs PHIUS Certification: How VIG Fits the Passive House Energy Balance for the full PHPP input guide and a worked energy balance example.

The bottom line

Vacuum insulated glass fits cleanly into CSI MasterFormat under 08 88 00 Special Function Glazing for standalone glazing specifications, or within the relevant window or curtain wall section for factory-glazed assemblies. The six performance attributes that define the product — center-of-glass U-factor, unit depth, frit edge seal, vacuum gap pressure, ISO 19916-1 compliance, and warranty term — are the criteria that belong in both the specification and the substitution clause.

Writing those criteria explicitly is what keeps the specification enforceable: a substitution request that cannot meet all six is not a valid substitution, regardless of how the whole-window U-factor compares on paper.

Download the THERMGLASS master spec table — a pre-formatted performance data table for the standard VIG configurations, ready to paste into a Division 08 section.

Run your configuration in the Architectural Configurator — center-of-glass U-factor, SHGC, and visible transmittance for your exact build, with the calculation basis cited for submittal use.

Questions about a specific project specification? Contact the team — drawings, the energy model target, and the frame system are enough to start a proper submittal package.

Frequently Asked Questions

Which CSI MasterFormat section covers vacuum insulated glass?

Division 08 — Openings. Specifically Section 08 80 00 (Glazing) or the more granular 08 81 00 (Glass Glazing). Performance-specified VIG belongs under the glazing section rather than the window section (08 50 00), because the glass unit is the specified product, not the complete window assembly.

What performance attributes should a VIG specification call out?

At minimum: center-of-glass U-value (W/m²·K or Btu/h·ft²·°F), SHGC, overall unit thickness, edge-seal type (glass frit, portless), coating type (hard-coat pyrolytic or soft-coat), and the calculation standard (EN 673 / ISO 19916-1). For historic projects, add profile dimensions and reversibility language. For acoustic applications, add the design-stage STC or Rw estimate.

What is the NBS equivalent for UK projects?

NBS Specification Section L40 (Glazing) covers performance-specified glazing in UK projects. The performance attributes are the same as the CSI approach — U-value to EN 673, SHGC, overall thickness, edge-seal type — but expressed in SI units and referenced to EN standards rather than NFRC. The substitution clause language is also analogous.

Related guides

All Technical Guides
Technical Guides

Passive Cooling and SHGC: How Vacuum Glazing Cuts Cooling Loads in Hot Climates

In cooling-dominated climates, solar heat gain through windows is often the single largest driver of peak cooling load. This guide explains how SHGC ratings work, why vacuum insulated glass outperforms standard triple pane on solar control, and how specifiers can use low-SHGC VIG to reduce mechanical cooling capacity and running costs.

10 min readRead guide