Industrial cold storage freezer warehouse corridor

Markets · Cold Storage

Cold storage glazing for the full temperature ladder

Warm-edge vacuum insulating glass for walk-in coolers, sub-zero freezers, and blast freeze chambers — with US (°F) and EU (°C) configurators, EN 1279 / EN 12150 / ISO 19916-1 standards framing, and glass surfaces kept above the dew point so anti-sweat heaters can be reduced or removed.

Design basis: standalone VIG COG 0.081 Btu/h·ft²·°F (0.46 W/m²·K), hybrid 0.044 (0.25 W/m²·K) — EN 673 / ISO 19916-1 basis values, not rated at NFRC 100 conditions.

The Cold Chain Problem

One glass platform, every rung of the cold chain

Cold storage runs a temperature ladder from +32°F walk-in coolers down to −40°F blast freeze chambers — and every rung multiplies the conductive load through the glazing. Conventional double-pane IGU doors operate at or below the dew point of ambient air at most of that ladder, driving continuous condensation, anti-sweat heater draw, and compressor overload. THERMGLASS Warm-Edge VIG is designed to remove that failure mode across the full range, with makeup recommendations matched to each temperature zone.

This page consolidates the corrected operating temperature ranges from both THERMGLASS cold storage configurators — US and EU bases — the governing standards (ISO 19916-1, EN 1279, EN 12150) as they are applied on the /methodology table, and the hedged anti-sweat heater wording used across the site. Pick your region's configurator below; both output a recommended makeup, U-values, condensation analysis, and a quote request.

Cold storage warehouse freezer aisle with refrigerated racks

Temperature Ranges

Operating temperature ranges — US and EU bases

The ranges below are the temperature zones as configured in the THERMGLASS configurators. Makeup recommendations shift from Standalone VIG to Hybrid VIG as interior temperature drops; blast freeze chambers carry additional requirements (tempered sub-lites, heated gasket).

United States (°F)

US configurator at /configurator/cold-storage — °F, USD landed-cost pricing.

Walk-in cooler+32°F to +41°F
Standalone VIG
Walk-in freezer−10°F to 0°F
Hybrid VIG
Blast / deep freeze−20°F to −40°F
Hybrid VIG + tempered sub-lites + heated gasket (mandatory)

EU / UK (°C)

EU/UK configurator at /configurator/eu-cold-storage — °C, EUR pricing. Blast freeze default: −35°C.

Cooler0°C to +5°C
Standalone VIG
Medium temp−5°C to 0°C
Hybrid VIG
Freezer−18°C to −23°C
Hybrid VIG
Deep freeze−23°C to −40°C
Hybrid VIG
Blast freeze (default −35°C)−30°C to −40°C
Hybrid VIG + tempered sub-lites + heated gasket (mandatory)

Applications

Where THERMGLASS Performs in the Cold Chain

Walk-In Coolers & Refrigerated Warehouses

Positive-temperature walk-in coolers (+32°F to +41°F) and refrigerated warehouses. THERMGLASS Standalone VIG handles cooler doors and vision panels; Hybrid VIG is specified once interiors drop below freezing.

Walk-In Freezers

Sub-zero walk-in freezers at −10°F to 0°F (US) or −18°C to −23°C (EU). Hybrid VIG — a vacuum unit bonded to an IGU cavity — holds CR 85+ and a whole-unit U-factor of approximately 0.12 Btu/h·ft²·°F at the configurator's default frame assumptions (thermally broken aluminum, 20% frame-area fraction).

Blast Freeze Chambers & Cold Chain

Blast freeze chambers at −30°C to −40°C (EU design default −35°C) or −20°F to −40°F (US). Hybrid VIG with tempered sub-lites per EN 12150 and heated gasket systems (mandatory in these chambers) — standalone VIG is not suitable at ΔT ≥ 60 K due to thermal bending stress and perimeter gasket seal risk.

Retail Display (Refrigeration Market)

Glass-door reach-in and open-front merchandising shares the same glass platform — see the Refrigeration market page for display-case specifics, NSF/ANSI 7 OEM cabinet framing, and store-ambient dew-point design.

Refrigeration market page

Key Benefits

Cold Storage Performance Advantages

71–84% Conductive Load Reduction vs. Reference IGU

THERMGLASS VIG reduces conductive heat gain through the glazing by 71–84% compared to a double-pane low-e IGU reference (COG U-factor 0.28 Btu/h·ft²·°F / 1.59 W/m²·K), cutting compressor runtime across the entire cold chain — largest in high-ΔT freezer and blast applications.

Glass Above the Dew Point — Heaters Reduced or Removable

Condensation Resistance ratings of 77–94 are designed to keep glass surface temperatures above the ambient dew point across standard operating conditions. Anti-sweat heater wiring can be reduced or removed in standard ambient conditions — ITO-coated heated glass remains available for high-humidity environments and extreme dew-point differentials.

Slim, Retrofit-Ready Profiles

Standalone VIG profiles from 6.3 mm fit existing door frame rebates designed for standard double-pane IGU — a direct drop-in retrofit for walk-in cooler and freezer doors without frame replacement.

Altitude Guidance Baked into the Configurators

Standalone VIG is altitude-neutral (fixed hard vacuum). The hybrid's second lite sits over a gas-filled cavity that is not altitude-neutral: gas-filled units require pressure equalization or capillary tubes when shipped to or installed at significant elevation — flagged in both configurators.

Standards

Standards basis — consistent with /methodology

The standards framing below mirrors the site methodology table. One caveat applies across all of them: for cold storage interiors (−18°C to −40°C), actual mean glass temperature sits well below the EN 673 standard-condition 10°C, so in-service U-values will differ from standard-condition figures — both configurators carry this caveat in their outputs.

ISO 19916-1

Primary VIG thermal standard

The primary thermal standard for vacuum insulating glass. THERMGLASS COG U-values (0.46 W/m²·K standalone, 0.25 W/m²·K hybrid) are reported at EN 673 standard conditions and converted to US units without a NFRC 100 boundary-condition adjustment — quote them only as EN 673-basis, converted values. COG values do not include frame or edge-seal contributions; whole-unit Uw uses the EN ISO 10077-1 area-weighted formula.

EN 1279

Hybrid IGU cavity (gas-filled component)

Applies to the gas-filled IGU cavity of hybrid VIG builds — gas concentration and loss rate, sealing-unit performance, and durability. Standalone VIG has no gas-filled cavity and sits outside EN 1279 scope; its vacuum gap is assessed under ISO 19916-1.

EN 12150

Toughened lites for blast/deep freeze hybrids

Thermally toughened soda-lime-silicate safety glass. Hybrid VIG builds for blast freeze and deep freeze chambers use toughened sub-lites to manage thermal bending stress at ΔT ≥ 60 K; heated gasket systems are mandatory in those chambers to protect the perimeter seal.

The full methodology table — including NFRC 100 boundary conditions, the EN ISO 10077-1 whole-unit formula, the DOE walk-in test-method rule (NFRC 102-2020 → ASTM C1199-14), and EU Uw per EN ISO 10077-1:2017 — is maintained on the /methodology page and is the authoritative reference for this site.

Compliance Data

Compliance & Standards Data

THERMGLASS cold storage glazing is engineered against the US and EU regulatory frameworks that govern refrigerated walk-ins, freezers, and blast freeze chambers. The following data reflects design-intent performance parameters for the THERMGLASS cold storage product line.

ASHRAE 90.1-2022 & DOE Walk-In Thresholds (US)

Below limit (calculated)

ASHRAE 90.1-2022 §6.4.3 sets maximum whole-unit U-factors for refrigerated case doors: 0.25 Btu/h·ft²·°F for refrigerated display case doors and 0.30 Btu/h·ft²·°F for walk-in cooler/freezer doors. THERMGLASS VIG whole-unit U-factors — area-weighted per the Cold Storage Configurator's default assumptions (thermally broken aluminum frame, 20% frame-area fraction, ISO 10077-1) — are approximately 0.15 Btu/h·ft²·°F (Standalone VIG) and 0.12 Btu/h·ft²·°F (Hybrid VIG), roughly 1.7–2.5× below both thresholds. DOE commercial refrigeration equipment standards (10 CFR Part 431) require ≤0.30 Btu/h·ft²·°F.

ISO 19916-1 — Primary VIG Thermal Standard

EN 673-basis reporting, caveat carried

ISO 19916-1 is the primary thermal standard for vacuum insulating glass. THERMGLASS COG U-values are reported at EN 673 standard conditions (ΔT = 15 K, mean glass temperature 10°C); the US Btu figures are straight unit conversions of the EN 673 basis and are not rated at NFRC 100 boundary conditions. For cold storage interiors (−18°C to −40°C), actual mean glass temperature sits well below the 10°C standard condition — in-service U-values will differ, and both configurators carry this caveat.

EN 1279 — Hybrid IGU Cavity

Applies to the gas-filled cavity (hybrid)

For hybrid VIG builds, the conventional IGU cavity is a gas-filled insulating glass unit: EN 1279 governs gas concentration and loss rate, sealing-unit performance, and durability for that cavity. Standalone VIG has no gas-filled cavity and is out of EN 1279 scope — its vacuum gap is covered by ISO 19916-1.

EN 12150 — Toughened Lites (Blast/Deep Freeze)

Required for blast and deep freeze hybrids

Hybrid VIG builds for blast freeze and deep freeze chambers use thermally toughened sub-lites. EN 12150 governs the toughened soda-lime-silicate safety glass used in EU builds; the US configurator outputs note the equivalent tempered-glass treatment for US-specified assemblies. Tempering manages the thermal bending stress that makes standalone 6.3 mm VIG unsuitable at ΔT ≥ 60 K.

All compliance data reflects design-intent performance parameters. NSF/ANSI 7 certification is issued to completed OEM cabinet assemblies — not to individual glass components. ASHRAE 90.1 compliance requires certified NFRC 100 whole-window U-factor testing for the specific product and installation. Contact THERMGLASS for project-specific engineering documentation.

Technical Reading

From the THERMGLASS Technical Blog

Cold Storage

Vacuum Glass for Supermarket Refrigeration Doors

Vacuum glass cuts display-door heat gain and dramatically reduces anti-sweat heater duty — door U-values and heater watts, per ASHRAE Refrigeration 2022.

Read the guide
Cost & ROI

How to Calculate Vacuum Glass Payback: The Complete Guide

A step-by-step method for annual savings, simple payback and NPV, with a worked example from the THERMGLASS ROI Engine.

Read the guide
Cold Storage

Cold Storage Efficiency: The Hidden Cost of Poor Door Glazing

Quantifying compressor energy waste from high-U glass in walk-in coolers and freezers using ASHRAE Refrigeration 2022 load models (Ch. 24) — with real payback calculations.

Read the guide

Cold Storage Configurators

Spec your cold storage glazing

Pick the configurator that matches your market: the US tool works in °F and USD landed cost, the EU/UK tool in °C and EUR — both output a recommended makeup, COG and whole-unit U-values, condensation analysis, and a quote request.

Specify THERMGLASS for your cold storage project

Share your temperature zone, door schedule, and frame system — the engineering team returns a recommended makeup with thermal and condensation analysis.

FAQ

Frequently Asked Questions

The configurators cover the full cold chain ladder. US basis: walk-in coolers +32°F to +41°F (Standalone VIG), walk-in freezers −10°F to 0°F (Hybrid VIG), blast/deep freeze −20°F to −40°F (Hybrid VIG with tempered sub-lites and heated gasket). EU basis: coolers 0°C to +5°C (Standalone), medium temp −5°C to 0°C, freezers −18°C to −23°C, deep freeze −23°C to −40°C, and blast freeze −30°C to −40°C with a −35°C design default (Hybrid VIG, tempered sub-lites required, heated gasket mandatory).

ISO 19916-1 is the primary thermal standard for VIG — THERMGLASS COG U-values are reported at EN 673 standard conditions and converted to US units without a NFRC 100 boundary-condition adjustment. EN 1279 applies to the gas-filled IGU cavity of hybrid builds; standalone VIG has no gas-filled cavity and sits outside EN 1279 scope. EN 12150 governs the toughened sub-lites required on blast and deep freeze hybrids. The full methodology table is maintained on the /methodology page.

In standard ambient conditions, anti-sweat heater wiring can be reduced or removed: THERMGLASS VIG (Condensation Resistance 77–94) is designed to keep glass surface temperatures above the ambient dew point. For high-humidity environments and extreme dew-point differentials, an ITO-coated heated glass option remains available. ASHRAE 90.1-2022 §6.4.3.4 otherwise requires case-door anti-sweat heaters to be humidity-controlled or rated ≤7.1 W per linear foot.

ASHRAE 90.1-2022 §6.4.3 sets maximum whole-unit U-factors of 0.25 Btu/h·ft²·°F for refrigerated display case doors and 0.30 for walk-in cooler/freezer doors; DOE commercial refrigeration standards (10 CFR Part 431) require ≤0.30. THERMGLASS whole-unit U-factors — area-weighted per the Cold Storage Configurator’s default assumptions (thermally broken aluminum frame, 20% frame-area fraction) — are approximately 0.15 Btu/h·ft²·°F (Standalone VIG) and 0.12 (Hybrid VIG). NSF/ANSI 7 does not set a glass U-factor limit — it governs the completed OEM cabinet.

At interior temperatures of −30°C to −40°C the across-the-glazing temperature difference reaches ΔT ≥ 60 K, which creates thermal bending stress in the glass and risk at the perimeter gasket seal. A 6.3 mm standalone unit is not suitable there — the EU and US configurators both specify Hybrid VIG with tempered sub-lites (EN 12150) and a heated gasket as mandatory for blast freeze chambers.

Yes. THERMGLASS Standalone VIG profiles start at 6.3 mm — thin enough to fit most existing door frame rebates designed for standard double-pane IGU — enabling a direct drop-in retrofit of walk-in cooler and freezer doors without frame replacement. The flush glass-frit seal means unit depth equals the glass stack.

Use the US Cold Storage Configurator at /configurator/cold-storage for °F dimensions, USD landed-cost pricing, and ASHRAE 90.1/DOE/NSF compliance flags. Use the EU/UK tool at /configurator/eu-cold-storage for °C dimensions, EUR pricing, and EN ISO 23953 / EN 1279 / EN 12150 compliance notes. Both output a recommended makeup, COG and whole-unit U-values, and condensation analysis. The Cooler & Freezer Door Savings Calculator at /configurator/roi-refrigeration estimates compressor energy savings per door.

THERMGLASS lists a 15-year manufacturer’s warranty on standalone vacuum units, and a 10-year warranty on the conventional IGU component of hybrid VIG units. The written warranty document issued with your order governs — ask for the exact warranty documentation for your cooler, freezer, or blast freeze application before you specify.