Markets · Cold Storage
Cold storage glazing for the full temperature ladder
Warm-edge vacuum insulating glass for walk-in coolers, sub-zero freezers, and blast freeze chambers — with US (°F) and EU (°C) configurators, EN 1279 / EN 12150 / ISO 19916-1 standards framing, and glass surfaces kept above the dew point so anti-sweat heaters can be reduced or removed.
Design basis: standalone VIG COG 0.081 Btu/h·ft²·°F (0.46 W/m²·K), hybrid 0.044 (0.25 W/m²·K) — EN 673 / ISO 19916-1 basis values, not rated at NFRC 100 conditions.
The Cold Chain Problem
One glass platform, every rung of the cold chain
Cold storage runs a temperature ladder from +32°F walk-in coolers down to −40°F blast freeze chambers — and every rung multiplies the conductive load through the glazing. Conventional double-pane IGU doors operate at or below the dew point of ambient air at most of that ladder, driving continuous condensation, anti-sweat heater draw, and compressor overload. THERMGLASS Warm-Edge VIG is designed to remove that failure mode across the full range, with makeup recommendations matched to each temperature zone.
This page consolidates the corrected operating temperature ranges from both THERMGLASS cold storage configurators — US and EU bases — the governing standards (ISO 19916-1, EN 1279, EN 12150) as they are applied on the /methodology table, and the hedged anti-sweat heater wording used across the site. Pick your region's configurator below; both output a recommended makeup, U-values, condensation analysis, and a quote request.
Temperature Ranges
Operating temperature ranges — US and EU bases
The ranges below are the temperature zones as configured in the THERMGLASS configurators. Makeup recommendations shift from Standalone VIG to Hybrid VIG as interior temperature drops; blast freeze chambers carry additional requirements (tempered sub-lites, heated gasket).
United States (°F)
US configurator at /configurator/cold-storage — °F, USD landed-cost pricing.
EU / UK (°C)
EU/UK configurator at /configurator/eu-cold-storage — °C, EUR pricing. Blast freeze default: −35°C.
Applications
Where THERMGLASS Performs in the Cold Chain
Walk-In Coolers & Refrigerated Warehouses
Positive-temperature walk-in coolers (+32°F to +41°F) and refrigerated warehouses. THERMGLASS Standalone VIG handles cooler doors and vision panels; Hybrid VIG is specified once interiors drop below freezing.
Walk-In Freezers
Sub-zero walk-in freezers at −10°F to 0°F (US) or −18°C to −23°C (EU). Hybrid VIG — a vacuum unit bonded to an IGU cavity — holds CR 85+ and a whole-unit U-factor of approximately 0.12 Btu/h·ft²·°F at the configurator's default frame assumptions (thermally broken aluminum, 20% frame-area fraction).
Blast Freeze Chambers & Cold Chain
Blast freeze chambers at −30°C to −40°C (EU design default −35°C) or −20°F to −40°F (US). Hybrid VIG with tempered sub-lites per EN 12150 and heated gasket systems (mandatory in these chambers) — standalone VIG is not suitable at ΔT ≥ 60 K due to thermal bending stress and perimeter gasket seal risk.
Retail Display (Refrigeration Market)
Glass-door reach-in and open-front merchandising shares the same glass platform — see the Refrigeration market page for display-case specifics, NSF/ANSI 7 OEM cabinet framing, and store-ambient dew-point design.
Refrigeration market pageKey Benefits
Cold Storage Performance Advantages
71–84% Conductive Load Reduction vs. Reference IGU
THERMGLASS VIG reduces conductive heat gain through the glazing by 71–84% compared to a double-pane low-e IGU reference (COG U-factor 0.28 Btu/h·ft²·°F / 1.59 W/m²·K), cutting compressor runtime across the entire cold chain — largest in high-ΔT freezer and blast applications.
Glass Above the Dew Point — Heaters Reduced or Removable
Condensation Resistance ratings of 77–94 are designed to keep glass surface temperatures above the ambient dew point across standard operating conditions. Anti-sweat heater wiring can be reduced or removed in standard ambient conditions — ITO-coated heated glass remains available for high-humidity environments and extreme dew-point differentials.
Slim, Retrofit-Ready Profiles
Standalone VIG profiles from 6.3 mm fit existing door frame rebates designed for standard double-pane IGU — a direct drop-in retrofit for walk-in cooler and freezer doors without frame replacement.
Altitude Guidance Baked into the Configurators
Standalone VIG is altitude-neutral (fixed hard vacuum). The hybrid's second lite sits over a gas-filled cavity that is not altitude-neutral: gas-filled units require pressure equalization or capillary tubes when shipped to or installed at significant elevation — flagged in both configurators.
Standards
Standards basis — consistent with /methodology
The standards framing below mirrors the site methodology table. One caveat applies across all of them: for cold storage interiors (−18°C to −40°C), actual mean glass temperature sits well below the EN 673 standard-condition 10°C, so in-service U-values will differ from standard-condition figures — both configurators carry this caveat in their outputs.
ISO 19916-1
The primary thermal standard for vacuum insulating glass. THERMGLASS COG U-values (0.46 W/m²·K standalone, 0.25 W/m²·K hybrid) are reported at EN 673 standard conditions and converted to US units without a NFRC 100 boundary-condition adjustment — quote them only as EN 673-basis, converted values. COG values do not include frame or edge-seal contributions; whole-unit Uw uses the EN ISO 10077-1 area-weighted formula.
EN 1279
Applies to the gas-filled IGU cavity of hybrid VIG builds — gas concentration and loss rate, sealing-unit performance, and durability. Standalone VIG has no gas-filled cavity and sits outside EN 1279 scope; its vacuum gap is assessed under ISO 19916-1.
EN 12150
Thermally toughened soda-lime-silicate safety glass. Hybrid VIG builds for blast freeze and deep freeze chambers use toughened sub-lites to manage thermal bending stress at ΔT ≥ 60 K; heated gasket systems are mandatory in those chambers to protect the perimeter seal.
The full methodology table — including NFRC 100 boundary conditions, the EN ISO 10077-1 whole-unit formula, the DOE walk-in test-method rule (NFRC 102-2020 → ASTM C1199-14), and EU Uw per EN ISO 10077-1:2017 — is maintained on the /methodology page and is the authoritative reference for this site.
Compliance Data
Compliance & Standards Data
THERMGLASS cold storage glazing is engineered against the US and EU regulatory frameworks that govern refrigerated walk-ins, freezers, and blast freeze chambers. The following data reflects design-intent performance parameters for the THERMGLASS cold storage product line.
ASHRAE 90.1-2022 & DOE Walk-In Thresholds (US)
ASHRAE 90.1-2022 §6.4.3 sets maximum whole-unit U-factors for refrigerated case doors: 0.25 Btu/h·ft²·°F for refrigerated display case doors and 0.30 Btu/h·ft²·°F for walk-in cooler/freezer doors. THERMGLASS VIG whole-unit U-factors — area-weighted per the Cold Storage Configurator's default assumptions (thermally broken aluminum frame, 20% frame-area fraction, ISO 10077-1) — are approximately 0.15 Btu/h·ft²·°F (Standalone VIG) and 0.12 Btu/h·ft²·°F (Hybrid VIG), roughly 1.7–2.5× below both thresholds. DOE commercial refrigeration equipment standards (10 CFR Part 431) require ≤0.30 Btu/h·ft²·°F.
ISO 19916-1 — Primary VIG Thermal Standard
ISO 19916-1 is the primary thermal standard for vacuum insulating glass. THERMGLASS COG U-values are reported at EN 673 standard conditions (ΔT = 15 K, mean glass temperature 10°C); the US Btu figures are straight unit conversions of the EN 673 basis and are not rated at NFRC 100 boundary conditions. For cold storage interiors (−18°C to −40°C), actual mean glass temperature sits well below the 10°C standard condition — in-service U-values will differ, and both configurators carry this caveat.
EN 1279 — Hybrid IGU Cavity
For hybrid VIG builds, the conventional IGU cavity is a gas-filled insulating glass unit: EN 1279 governs gas concentration and loss rate, sealing-unit performance, and durability for that cavity. Standalone VIG has no gas-filled cavity and is out of EN 1279 scope — its vacuum gap is covered by ISO 19916-1.
EN 12150 — Toughened Lites (Blast/Deep Freeze)
Hybrid VIG builds for blast freeze and deep freeze chambers use thermally toughened sub-lites. EN 12150 governs the toughened soda-lime-silicate safety glass used in EU builds; the US configurator outputs note the equivalent tempered-glass treatment for US-specified assemblies. Tempering manages the thermal bending stress that makes standalone 6.3 mm VIG unsuitable at ΔT ≥ 60 K.
All compliance data reflects design-intent performance parameters. NSF/ANSI 7 certification is issued to completed OEM cabinet assemblies — not to individual glass components. ASHRAE 90.1 compliance requires certified NFRC 100 whole-window U-factor testing for the specific product and installation. Contact THERMGLASS for project-specific engineering documentation.
Technical Reading
From the THERMGLASS Technical Blog
Vacuum Glass for Supermarket Refrigeration Doors
Vacuum glass cuts display-door heat gain and dramatically reduces anti-sweat heater duty — door U-values and heater watts, per ASHRAE Refrigeration 2022.
Read the guideHow to Calculate Vacuum Glass Payback: The Complete Guide
A step-by-step method for annual savings, simple payback and NPV, with a worked example from the THERMGLASS ROI Engine.
Read the guideCold Storage Efficiency: The Hidden Cost of Poor Door Glazing
Quantifying compressor energy waste from high-U glass in walk-in coolers and freezers using ASHRAE Refrigeration 2022 load models (Ch. 24) — with real payback calculations.
Read the guideCold Storage Configurators
Spec your cold storage glazing
Pick the configurator that matches your market: the US tool works in °F and USD landed cost, the EU/UK tool in °C and EUR — both output a recommended makeup, COG and whole-unit U-values, condensation analysis, and a quote request.
Specify THERMGLASS for your cold storage project
Share your temperature zone, door schedule, and frame system — the engineering team returns a recommended makeup with thermal and condensation analysis.
FAQ


