Markets · Marine & Offshore
Marine & Offshore Glazing
ISO 10077-1 whole-unit U-values, salt-spray corrosion resistance, and IMO fire-rated glazing advisory for superyachts, commercial vessels, ferries, and offshore platforms.
Performance basis: COG U-values calculated per EN 673; whole-unit Uw calculated per ISO 10077-1; Rw per EN ISO 717-1 — calculated values, not laboratory test data. Classification type approval is in progress.
Marine Applications
Built for the Harshest Marine Environments
THERMGLASS VIG delivers center-of-glass U-values of 0.46 W/m²K (standalone) and 0.22 W/m²K (hybrid) with standalone units from 6.3 mm (3 mm lites) to 10.3 mm (5 mm lites) overall, and hybrid builds at ≈20.3–26 mm — engineered to withstand salt-spray corrosion, structural vibration, and the extreme thermal differentials of Arctic and tropical operating regions.
Marine-premium edge seal with enhanced corrosion-resistant framing is designed to support DNV and Lloyd's Register classification documentation. IMO fire-rated glazing advisory is integrated into the Marine Configurator — actual compliance requires type-approved, FTP Code-tested glazing certified by an accredited laboratory.
0.46 W/m²K
COG U-Value (Standalone)
0.22 W/m²K
COG U-Value (Hybrid)
6.3–10.3 mm standalone · ≈20.3–26 mm hybrid
Profile Thickness
38–42 dB
Acoustic (Rw, approx.)
~50% lighter than a 24 mm triple-pane (4 mm lites) · ≈ same glass weight as dual-pane
Weight vs. Reference IGUs
ISO 10077-1, EN 673 — DNV/LR documentation support in progress
Standards Basis
Applications
Where THERMGLASS Performs
Superyachts & Luxury Vessels
Ultra-slim standalone units — 6.3 mm with 3 mm lites, up to 10.3 mm with 5 mm lites — fit bespoke frame systems without structural redesign. Approximate Rw 38 dB (standalone) to Rw 42 dB (laminated or hybrid build) acoustic performance reduces engine and sea-state noise in saloons, staterooms, and wheelhouses.
Commercial Ferries & Passenger Ships
Whole-unit Uw values calculated to ISO 10077-1 support HVAC load reduction and operational emissions documentation. Reduced glazing U-value lowers heating and cooling demand across large glazed areas.
Offshore Platforms & Workboats
Hybrid VIG makeup rated for ΔT extremes in Arctic and sub-Arctic operating regions. Polar Code thermal advisory built into the Marine Configurator flags compliance requirements automatically.
Naval & Coast Guard Vessels
Structural integrity under vibration and dynamic loading. IMO fire-rated glazing toggle in the Marine Configurator outputs a compliance advisory for vessels subject to SOLAS Chapter II-2 requirements — actual fire-rated glazing must be type-approved and FTP Code tested.
Key Benefits
Marine-Grade Performance Advantages
ISO 10077-1 Whole-Unit U-Values
Area-weighted Uw calculation per ISO 10077-1 — standalone 0.46 W/m²K COG; hybrid 0.22 W/m²K COG. Actual frame area ratio varies by glazing type and vessel design.
Marine-Premium Edge Seal
Enhanced corrosion-resistant edge seal rated for continuous salt-spray exposure. Adder pricing built into the Marine Configurator: $300/m² standalone, $700/m² hybrid.
Rw 38–42 dB Acoustic Performance
EN ISO 717-1 rated acoustic attenuation. Standalone VIG achieves approximately Rw 38 dB; the upper range (Rw 42 dB) requires a laminated or hybrid build. Reduces engine noise, sea-state impact, and port ambient noise in occupied spaces.
Weight Reduction vs. 24mm Triple-Pane
Monolithic VIG (6.3 mm unit with 3 mm lites) is approximately 50% lighter than a conventional 24mm triple-pane IGU of equivalent glass area. Glass weight is roughly the same as the dual-pane IGUs most vessels already have — the ~50% saving applies specifically against 24 mm triple-pane builds with 4 mm lites. Weight advantage narrows for hybrid builds (up to ≈26 mm overall profile). Improves vessel stability, fuel efficiency, and structural load margins.
Polar Code & Arctic Compliance
Hybrid VIG makeup recommended for operating regions with ΔT ≥ 40K. The Marine Configurator outputs a Polar Code thermal advisory for Arctic and global-trading routes automatically.
DNV & Lloyd's Register Documentation
Performance data formatted to support classification society energy assessments. ISO 10077-1 Uw values, EN 673 COG U-values, and marine-premium edge seal documentation available on request. Type approval in progress.

Retrofit Fit
Re-glaze in place — keep the frames
Most marine window and portlight openings can be re-glazed without re-cutting frames: standalone units from 6.3 mm (3 mm lites) drop into existing cutouts, and the flush glass-frit seal keeps unit depth equal to the glass stack. Weight drops roughly 50% versus 24 mm triple-pane — easing door, hatch, and sliding-window loads — while the marine-premium edge seal stands up to continuous salt-spray exposure. For hybrid builds in standard IGU pockets, overall depth is ≈20.3–26 mm.
- Glazing-only swap into existing cutouts — no re-cutting or frame redesign
- 0.46 W/m²K COG (0.22 W/m²K hybrid) with Rw 38–42 dB acoustic performance
- Marine-premium edge seal rated for continuous salt-spray exposure
Technical Reading
From the THERMGLASS Technical Blog
Vacuum Glass for Marine Vessels: Condensation and Weight
Bridge glass fogs from the first cold current. How vacuum glazing keeps wheelhouse glass dry and light — and what it changes for fuel and refits.
Read the guideThermal Insulation Compared: Vacuum Glass, Triple-Pane, Low-E IGU
Side-by-side analysis of U-values, SHGC, weight, and thickness across glazing types — with data grounded in EN 673 and NFRC 100 test standards.
Read the guideCalculating VIG Payback: The ASHRAE Method, Step by Step
A step-by-step methodology for calculating NPV, payback period, and annual energy savings from VIG upgrades using U-value differentials and ASHRAE steady-state models.
Read the guideSpecify THERMGLASS for Your Vessel
Use the Marine Configurator to model ISO 10077-1 U-values, acoustic performance, Polar Code compliance, and USD pricing with marine-premium edge seal — then contact us for a sample or full specification package.
FAQ