Architectural & Commercial

VIG & Hybrid Configurator

Specify standalone Vacuum Insulating Glass or Hybrid VIG substrates. Get instant pricing, IECC 2021 compliance, and full performance data.

All Configurators
Trade accounts can save this configuration to their dashboard.Sign in to save

Vacuum Insulating Glass — US & Canada

Specify standalone VIG (COG U-factor 0.081 Btu/h·ft²·°F, R-12.3) or Hybrid VIG (0.039, R-25.6) for new construction, curtain wall, storefront, and window replacement. IECC 2021 climate zone compliance checked instantly.

Passive House, LEED & ENERGY STAR

Hybrid VIG achieves whole-window U-factors below 0.14 Btu/h·ft²·°F with a thermal-break aluminium frame — meeting PHI Passive House and ENERGY STAR v7 Northern zone requirements in a 26 mm profile.

Configuration Type

A single vacuum insulating glass unit — two lites bonded with a warm-edge pillar grid and glass frit edge seal. Profile from 6.3 mm. Best for windows, skylights, and curtain wall.

Dimensions & Quantity

Enter the glass size (not the rough opening). Minimum 12" × 12". Maximum 60" × 98".

Glass Substrate

Low-E Coating

Manufacturer

Shape

Frame & Installation

Frame Material

Typical frame U-factor for Thermal Break Aluminum:0.40 Btu/h·ft²·°F

Leave blank to use the typical value for the selected frame material.

Visible frame face width in inches. Leave blank for the 80/20 default split; when entered, the frame-area fraction is computed from your window dimensions (ISO 10077-1 perimeter band, treated as an approximation).

Spacer Type

Installation Type

Project Context

IECC Climate Zone

IECC 2021 whole-window U-factor maximums are applied automatically for the selected zone.

VIG uses a fixed hard vacuum — altitude-neutral. No differential pressure concern unlike gas-filled IGUs.

Primary Orientation

Shading Conditions

Code / Certification Target

IECC 2021 Zone 5 maximum whole-window U-factor:0.30 Btu/h·ft²·°F

Additional Notes

Estimate

Enter dimensions above to see an instant estimate.

Performance Datasheet

Center-of-Glass (COG)

U-Factor (NFRC Winter, COG)

0.081 Btu/h·ft²·°F

Base (uncoated): 0.081 Btu/h·ft²·°F = 0.46 W/m²·K · vs. Triple Pane IGU (COG): 0.10 – 0.14 Btu/h·ft²·°F

Center-of-Glass R-Value

R-12.3

vs. Triple Pane IGU (COG): R-7 to R-10

Visible Light Transmittance (VLT)

~81%

vs. Triple Pane IGU (COG): ~70–75%

Solar Heat Gain Coefficient (SHGC)

~0.76

vs. Triple Pane IGU (COG): 0.35–0.55 (uncoated) / 0.20–0.35 (Low-E)

Acoustic Performance (STC)

STC 35–39

vs. Triple Pane IGU: STC 32–36

Overall Profile Thickness

6.3–10.3 mm (3/4/5 mm lites)

vs. Triple Pane IGU: ~36 mm (1-7/16")

COG values per NFRC 100 simulation. Actual performance varies with coating lot, substrate thickness, and installation conditions.

Sign in to download technical specifications

Enter width, height, and quantity above to see whole-window U-factor and code compliance results.

Climate & Site Context

Heating Degree Days

5,400–7,200

Zone 5 typical

Cooling Degree Days

250–500

Zone 5 typical

Condensation Resistance (est. CR)

CR 87

Excellent — low condensation risk in most climates and occupancy types.

Solar Load Rating

Moderate

Balanced solar exposure — consider SHGC ≤ 0.40 for mixed climates.

HDD/CDD values are IECC zone-typical averages. Actual site data may vary.

All performance data is based on simulation models and published manufacturer data. THERMGLASS makes no warranty of fitness for a particular purpose. Consult a licensed engineer for project-specific specifications.

Frequently Asked Questions

The three standalone profiles (6.3, 8.3, and 10.3 mm) plus hybrid VIG + IGU cavity assemblies, with Low-E coating options and frame/gasket systems.