Refrigeration VIG

Cooler & Freezer Door Savings Calculator

Calculate conduction and anti-sweat heater savings for THERMGLASS VIG in walk-in coolers, freezer cases, and refrigerated display cases. VIG keeps the inner glass above the dew point, so doors stay clear after every opening — product stays visible and heater energy never enters the case. Model per ASHRAE Refrigeration Handbook 2022.

System Inputs

US mode — U-values in Btu/h·ft²·°F · costs in USD

Glass-door frozen food cases (ice cream, frozen meals)

Typical reach-in door glass: 0.75–1.0 m² per door

Include anti-sweat heater savings

What percentage of your doors have anti-sweat heater wires? 100% = all doors heated (typical legacy single-pane install). Adjust for mixed fleets.

100%
0%50%100%
26 W/m(7.9 W/ft)
16 W/m (4.9 W/ft) — low26 W/m default40 W/m (12.2 W/ft) — high

W per meter of door perimeter — ASHRAE Refrig. 2022 §14, Table 14-3. Typical: 16–40 W/m. Default 26 W/m (≈ 8 W/ft).

Standalone VIG typical: 0.45–0.55 W/m²·K · Hybrid VIG: 0.30–0.40

Typical VIG door premium over standard double-pane: $300–$500 per door

Results

ASHRAE Refrig. 2022
ΔT: 40°CHours/day: 24Total area: 8.4 m²U delta: 3.3 W/m²·K

Cooling-only model. Refrigeration savings are compressor electricity only — no heating stream. Solar gain through door glazing is excluded (negligible vs. ΔT-driven conduction). Defrost cycle reduction is a real secondary benefit but is not modelled here.

Annual Energy Savings

Annual cost savings$2.0kper year
Conduction saved3.9 MWhcompressor kWh/yr
Baseline heat gain11.2 MWhbaseline compressor load/yr
VIG heat gain1.5 MWhVIG compressor load/yr
ASH saved12.9 MWhheater + compressor kWh/yr
Total energy saved16.8 MWhconduction + ASH kWh/yr

Anti-Sweat Heater Elimination

Estimated door perimeter: 4.06 m (13.3 ft) per door · 26 W/m (7.9 W/ft)
Heater wire draw eliminated9.2 MWhresistive heating removed
Compressor load removed3.7 MWhheat no longer added to case
ASH cost savings$1.6kheater + compressor combined
Conduction: $466ASH: $1.6k
23% conduction77% ASH

Payback & Investment

Simple payback1.9 yearsExcellent — within equipment replacement cycle
Incremental cost$3.8kVIG premium over baseline

Net Present Value

NPV at 10 yr$13.5k
NPV at 15 yr$20.7k

NPV = discounted cumulative savings minus incremental cost. Positive = net financial benefit over the period.

Carbon Impact

Annual CO₂ reduction6.5 t CO2per year
Lifetime CO₂ (15 yr)97.4 t CO2total avoided emissions

EN ISO 52016-1:2017 · Steady-state conduction model per ASHRAE Refrigeration Handbook 2022 §14. Heat gain = U × A × ΔT × hours/day × 365. Compressor energy = heat gain ÷ COP. Anti-sweat heater savings: heater wire draw + compressor load removed when ASH is eliminated. Covers conduction and ASH streams — defrost cycle reduction excluded.

Export PDF Report

3-page branded report — cover, results, and methodology

Assumptions: Discount rate 5% · Energy escalation 2.5%/yr · $0.12/kWh · ASH 100% of doors · Cooling only