Cost & ROI

Energy Savings Calculator Guide: Accurate Results for VIG Projects

How to use THERMGLASS's six ROI engines correctly — input assumptions, fuel type selection, climate zone data, and interpreting NPV outputs for VIG projects.

Ross Yudin, Managing Partner — THERM GLASS GROUP LLC
Share
Energy Savings Calculator Guide: Accurate Results for VIG Projects

An energy savings calculator is only as accurate as its inputs. THERMGLASS operates six ROI engines — for architectural, refrigeration, marine, heavy equipment, Passive House residential, and BIPV + VIG applications — each built on engineering-backed thermal models.

The Six ROI Engines and Their Underlying Models

Architectural ROI Engine

Model: ASHRAE Handbook of Fundamentals + NREL TMY3 / JRC PVGIS-5 solar irradiance data Analysis horizon: 25 years

Refrigeration ROI Engine

Model: ASHRAE Refrigeration Handbook 2022, Chapters 15 and 24 Analysis horizon: 15 years

Marine ROI Engine

Model: ASHRAE HVAC Applications 2023, Chapter 11 / DNV Rules for Ships Analysis horizon: 20 years

Heavy Equipment ROI Engine

Model: SAE J1503 cab thermal model Analysis horizon: 10 years

Passive House ROI Engine

Model: PHI / PHIUS residential criteria with ISO 10077-1 whole-window Uw inputs Analysis horizon: multi-period NPV scenarios

BIPV + VIG ROI Engine

Model: dual-stream analysis — architectural thermal savings plus photovoltaic generation revenue

Getting Accurate Inputs

Glazed Area

Enter the total glazed area you're upgrading, not the total window opening. For curtain wall systems, use the vision glass area only.

Baseline U-Value

Use the whole-window U-value (Uw), not the center-of-glass value. If unavailable, use the engine's default: 0.45 Btu/h·ft²·°F (US — a double-pane low-E whole-window, ≈2.56 W/m²·K) or 1.40 W/m²·K (EU, the same build on the EN basis).

VIG U-Value

  • EU default: 0.73 W/m²·K (ISO 10077-1 derived)
  • US default: 0.13 Btu/h·ft²·°F

Fuel Type and Cost

Fuel TypeUS DefaultEU Default
Natural gas$1.35/therm€1.10/m³
Heating oil$4.20/gallon€1.45/litre
Electric resistance$0.16/kWh€0.28/kWh
District heat$0.10/kWh_th€0.11/kWh_th

Enter your actual utility rate — using the default when your actual rate is 40% higher will understate your ROI proportionally.

Interpreting the Outputs

Simple Payback Period

Total installed VIG cost ÷ annual energy savings. A quick filter: under 5 years is almost certainly NPV-positive; over 15 years is marginal.

25-Year NPV

Present value of all future energy savings, discounted at the specified rate, minus the initial investment. NPV is the correct decision metric for capital allocation.

Common mistake: Treating NPV as linear. A 10-year NPV is not half of a 25-year NPV — always compute via the annuity formula.

Annual CO₂ Avoided

Calculated using fuel-specific emission factors: natural gas 0.181 kg CO₂/kWh thermal; heating oil 0.270 kg CO₂/kWh thermal.

Common Calculation Errors

  • Using COG U-values instead of whole-window Uw
  • Ignoring cooling savings in warm climates
  • Using list price instead of installed cost premium
  • Not running sensitivity analysis on energy costs

Open the ROI Engine for your application and run your project numbers.

Key Takeaways

  • Use whole-window Uw values (ISO 10077-1) for both baseline and VIG inputs
  • Enter your actual fuel cost and electricity rate
  • The architectural engine calculates both heating and cooling savings
  • NPV is the correct decision metric; simple payback is a quick filter only
  • Each engine exports a PDF report for energy documentation and capital presentations

Keep reading

The defaults above are starting points, not verdicts. The VIG vs triple glazing payback sweep shows how much climate zone, heating fuel, and the installed premium each move the answer before you commit to an assumption.

Skip the manual inputs where it matters: the architectural ROI configurator runs the same assumptions and returns a payback estimate for your building.

Frequently Asked Questions

Which ROI engine should I use for my project type?

Use the architectural engine for commercial and residential buildings, the cold-storage engine for walk-in coolers and freezers, the marine engine for vessels, the heavy-equipment engine for machine cabs, the passive-house engine for PHI/PHIUS projects, and the BIPV engine for building-integrated photovoltaic facades. Each engine documents its own methodology on the methodology page.

How accurate are the THERMGLASS ROI engine outputs?

The engines are specification-assistance tools, not certified energy models. Outputs are indicative values derived from published engineering standards (ASHRAE, EN 673, ISO 19916-1) with documented assumptions. They are accurate enough for feasibility analysis and design-stage decisions; verify by independent energy modelling before use in permit submissions or procurement contracts.

What inputs have the biggest effect on the payback calculation?

Energy price and glazing area dominate. A doubling of energy price halves the payback period. Climate zone (HDD/CDD) and the delta between current and target U-value set the annual savings ceiling. Installed cost per square foot sets the numerator. Run the engine with your actual energy price and area before drawing conclusions from the default example.

Related guides

All Cost & ROI

Run your project numbers.

Use the THERMGLASS ROI engines to calculate energy payback for your specific application.

Open the configurators