Passive House

Modeled: townhouse deep retrofit, passive-house target

1970s urban townhouse — original sashes retained, glazing upgraded in place

Modeled scenario using THERMGLASS calculators — not a completed installation. Figures are calculation-derived; see the outcome note at the end of this page.

Share

The Problem

The retrofit brief was a deep-energy upgrade to passive-house-level envelope performance without discarding the building's original window frames. In a deep retrofit the glazing is usually the weak link — and the obvious fix, triple glazing, is the one that doesn't fit: a 30-plus-millimetre triple-glazed build needs sashes and reveals designed around it, which the retained frames could never accept.

The comfort problem was as pressing as the thermal one. Old glazing turns every winter evening near a window into a radiant asymmetry problem: cold glass surfaces pull heat from occupants standing metres away, and the thermostat compensates by overheating the rest of the room.

Condensation risk rounded out the brief. Single- and early-double-glazed units run interior surface temperatures well below the winter dew point, fogging at the coldest corners of the sash and feeding moisture into the reveal — exactly the failure mode a deep retrofit is supposed to eliminate.

The Solution

The refit re-glazes the retained sashes with 6.3 mm standalone vacuum insulated glass — a glass stack that fits rebates triple glazing cannot touch. New openings take hybrid units, pairing the vacuum pane with a conventional IGU cavity at roughly 20.3–26 mm overall for the lowest U-values in the range.

Whole-window performance was modeled through the ROI engine at the ISO 10077-1 basis with a thermally-broken frame — the same conservative default the engine ships with (0.73 W/m²·K EU basis) until certified test data supersedes it. Perimeter specification followed standard warm-edge practice to keep the edge zone above the condensation risk line.

The comfort mechanism is the same physics as every other vacuum build: with almost no gas in the gap, the inner lite sits close to room temperature, which removes the radiant chill zone at the glass, steadies the interior surface above the winter dew point, and lets the heating system cycle instead of fighting a permanent cold sink at every window.

Modeled Outcomes

Figures are modeled outputs calculated from published methodology and the THERMGLASS ROI engine — not laboratory or field measurements. Run the linked calculator for project-specific numbers.

Whole-window Uw

≈0.73 W/m²·K

Modeled per ISO 10077-1 with a thermally-broken aluminium frame at a 20% frame fraction — the ROI engine's conservative default, pending certified test data.

Inner surface temp

≈63 °F at 70 °F / 0 °F

Modeled inner-surface temperature at the published design condition — the mechanism behind both the comfort gain and the condensation elimination.

Profile depth

6.3 mm

The standalone build fits the original sash rebates; hybrid openings at ≈20.3–26 mm reach the lowest U-values in the range.

Heating demand

$123.43/yr at defaults

The Passive House ROI engine's default scenario (220 sq ft of glazing, IECC zone 5 at 6,300 HDD, double-pane low-E whole-window baseline, heat-pump COP 3.0, $0.16/kWh, 2.5% escalation) returns $123.43/yr and a ≈39-year simple payback (break-even ≈28 years with escalation); the linked calculator prices your climate zone, fuel, and tariff over a 25-year horizon.

Put numbers on your project

Model the same glazing decision for your own project — dimensions, climate, and rates in, project-specific savings out.

Technical Reading

Passive House

Passive House Windows: Can Vacuum Glass Hit 0.80?

The Passive House window criterion is Uw ≤ 0.80 W/m²K. Here is the center-of-glass and frame math showing how vacuum insulated glass reaches it — and what to verify.

Read the guide
Glazing Comparison

Vacuum Glass vs. Triple-Pane: U-Value, Weight, Cost

Vacuum glass vs. triple-pane compared: center-of-glass U-values, unit depth, weight, and installed-cost drivers — the spec-level comparison for your next project.

Read the guide
Technical Guides

Vacuum Insulated Glass Explained: U-Values, Specs, Uses

How vacuum insulated glass reaches triple-pane-class U-values in a 6.3 mm build: the physics, the spec numbers, and where VIG earns its keep.

Read the guide
Glazing Comparison

Sound, Condensation, Payback: Vacuum Glass vs. Triple-Pane

The engine-backed verdict: vacuum glass vs. triple-pane on U-values, weight, acoustics, condensation margin, and payback at exact default inputs.

Read the guide
Glazing Comparison

When Vacuum Glass Pays Back Faster Than Triple-Pane

One scenario is an anecdote. We swept climate zone, heating fuel, and installed cost through the ROI engine to map where VIG-over-triple-pane payback actually moves.