Markets · RV & Mobile
A warmer, clearer RV in every season
VIG windows hold heat, stop fogging and weigh less — for Class A/B/C motorhomes, travel trailers, fifth wheels and van conversions.

Key Benefits
Why VIG for RV & Mobile Glazing
Passive Defogging
COG U-factor 0.081 Btu/h·ft²·°F (standalone) keeps the interior glass surface above dew point in most North American climates — glass stays clear on cold mornings without heater wiring.
About one-third less glass than triple-pane
VIG uses two lites where a triple-pane uses three — at equal lite thickness that is roughly one-third less glass. The often-quoted "50% lighter" figure only holds against a 24 mm triple-pane built with thicker 4 mm lites. Against the dual-pane units most RVs actually use, glass weight is roughly similar — the VIG benefit there is insulation, fog-free glass and slim fit, not big weight savings.
Solar Control for All Climates
Soft-coat Low-E options reduce SHGC to 0.17–0.40, cutting rooftop A/C run time in desert travel. Clear-substrate configurations maximize passive solar gain for cold-climate full-timers.
Thin Profile — Frame Compatible
Standalone VIG at 6.3 mm fits most existing RV aluminum and vinyl frame rebates without structural modification. Rubber gasket and direct-glaze options available for van conversions.
FMVSS 205 / Z26.1 — Certification in Progress
Tempered (AS-2) and laminated PVB/SGP (AS-1) substrates are produced to ANSI Z26.1 requirements — but the finished VIG unit is what gets tested and DOT-marked under FMVSS 205, and that unit certification is in progress. Until it completes, unmarked glass cannot be installed in a road vehicle. Current status is in the certification box below.
Four-Season Design
Designed for −40 °F to +185 °F operation. The warm-edge spacer eliminates the cold edge band that causes condensation and frame damage in conventional double-pane RV windows.

Retrofit Fit
Swap the glass — keep the frames
Most RV windows can be re-glazed without touching the frame: standalone units at 6.3 / 8.3 / 10.3 mm (3/4/5 mm lites) fit most existing aluminum and vinyl frame rebates, and the flush glass-frit seal keeps unit depth equal to the glass stack. Every pound saved across 8–20 windows adds payload and fuel economy, and passive defogging keeps the glass clear on cold mornings without heater wiring. Rubber gasket and direct-glaze options cover van conversions.
- Fits most existing RV aluminum and vinyl frame rebates — no frame modification
- Passive defogging — interior glass surface stays above dew point in most climates
- About one-third less glass than triple-pane — and roughly the same weight as the dual-pane units most RVs use; FMVSS 205 / ANSI Z26.1 unit certification in progress (see status box)
Specification
Size Guide & Ordering Notes
THERMGLASS VIG is manufactured to order. Review the following before specifying.
For sizes outside the ranges above, validate your opening in the RV Configurator before requesting a quotation — custom flat panes within the factory size range are quoted per project.
Performance at a Glance
Standalone vs. Hybrid VIG
Standalone VIG
Hybrid VIG
COG U-factor per ISO 10292 / EN 673 methodology. Whole-unit Uw is an area-weighted approximation — not a certified NFRC 100 rating. SHGC is a combined estimate (substrate × Low-E factor) — not a certified NFRC 200 rating.
Compliance
Certification status
Glazing sold for US road use must be certified and DOT-marked under FMVSS 205 as a finished unit — substrate compliance alone does not qualify an assembly. Where each requirement stands today:
Get Started
Specify for Your Build
Use the RV Configurator to generate a live specification with U-factor, SHGC, condensation resistance, weight comparison, and indicative pricing. Submit for a formal quotation or engineering consultation.
Request a Consultation
Technical Resources
Download Documentation

Technology & Process Overview
Intelligent continuous warm edge vacuum glass production line — full technical overview.
Download PDF
Marine VIG Technical Pitch Deck
VIG performance specifications and application data for marine and vessel glazing.
Download PDF
Global VIG Industry Reference Sheet
Industry-wide VIG reference data, standards, and performance benchmarks.
Download PDF
VIG Technical Specification Sheet
Detailed specification data for THERMGLASS VIG panels across refrigeration applications.
Download PDF
Architectural Specification — Section 08 81 00
CSI MasterFormat specification for THERMGLASS VIG glazing. Ready to incorporate into project manual or print to PDF.
View Spec