BIPV + Warm-Edge VIG Analysis
Solar Glass Savings Calculator
Combines insulation savings from THERMGLASS VIG with electricity generated by built-in solar glass. US (ASHRAE/IECC) or EU (EN ISO 52016/PVGIS) methods, in imperial or metric units.
Project inputs
BIPV module type
Visible light transmittance (VLT)
Glazing area (ft²)
Facade orientation
Glazing tilt
State (IECC climate zone)
Baseline glazing (Btu/h·ft²·°F)
THERMGLASS VIG U-value (Btu/h·ft²·°F)
ISO 10077-1 derived (pre-NFRC/EN 673 type-approval). Update when certified data available.
SHGC — baseline / VIG
Heating fuel type
Fuel cost ($/therm)
Electricity tariff ($/kWh) — PV revenue + cooling
VIG premium ($/ft²)
BIPV module premium ($/ft²)
CIGS (Thin-Film)
CIGS — best efficiency-to-transparency ratio. Preferred for commercial facades where moderate VLT and high yield are both required.
POA irradiance: 780 kWh/m²/yr · HDD: 8,350 · U-delta: 0.170 Btu/h·ft²·°F
Stream 1 — Thermal savings (VIG)
Stream 2 — PV generation (BIPV)
Trade-offs & engineering notes
Heat build-up — laminated to VIG, solar cells cannot shed heat rearward, so they run warmer and lose output (−0.2 to −0.45% per °C). The derate above is already applied.
Daylight & winter gain — the PV layer reduces visible light transmittance (20% VLT selected) and blocks some winter passive solar gain; the cooling side of the model already reflects the lower solar factor.
Thermal stress — a sustained temperature difference between the outer PV laminate and the inner lite is a known stress case for vacuum glazing. Request our test data on this before specifying solar glass on VIG.
Combined return
Carbon reduction
Compliance indicators
✓ / ✗ indicates whether entered U-values meet the threshold — not certified compliance. Formal compliance requires NFRC 100/500 (US) or EN 673 / EN ISO 10077 (EU) certified test reports and project-specific engineering review. VIG U-values are pre-certification estimates.
Assumptions: Discount rate 5% · Energy escalation 2.5%/yr · $0.16/kWh · Module CIGS · Cooling included
Explore Other ROI Engines
Architectural ROI
Commercial & residential glazing — ASHRAE/IECC + EU EN ISO 52016 models
Refrigeration ROI
Walk-in coolers & freezer cases — ASHRAE 2022 §14, 15-yr model
Marine ROI
Vessel bridge & cabin glazing — route-weighted ΔT, 20-yr model
Heavy Equipment ROI
Construction & mining cab glazing — SAE J1503, 10-yr model
Passive House ROI
PHI/PHIUS/IECC residential — ASHRAE 2021 §18, multi-period NPV
All Configurators
Spec tools for US, EU, marine, cold storage, and heavy equipment
