BIPV + Warm-Edge VIG Analysis

Solar Glass Savings Calculator

Combines insulation savings from THERMGLASS VIG with electricity generated by built-in solar glass. US (ASHRAE/IECC) or EU (EN ISO 52016/PVGIS) methods, in imperial or metric units.

Project inputs

BIPV module type

Visible light transmittance (VLT)

Glazing area (ft²)

Facade orientation

Glazing tilt

State (IECC climate zone)

Baseline glazing (Btu/h·ft²·°F)

THERMGLASS VIG U-value (Btu/h·ft²·°F)

ISO 10077-1 derived (pre-NFRC/EN 673 type-approval). Update when certified data available.

SHGC — baseline / VIG

Heating fuel type

Fuel cost ($/therm)

Electricity tariff ($/kWh) — PV revenue + cooling

VIG premium ($/ft²)

BIPV module premium ($/ft²)

CIGS (Thin-Film)

CIGS — best efficiency-to-transparency ratio. Preferred for commercial facades where moderate VLT and high yield are both required.

POA irradiance: 780 kWh/m²/yr · HDD: 8,350 · U-delta: 0.170 Btu/h·ft²·°F

Stream 1 — Thermal savings (VIG)

Heating saved5.4 MWhper year
Cooling saved1.0 MWhper year
Thermal savings$416per year
Total thermal6.5 MWhdelivered energy/yr

Stream 2 — PV generation (BIPV)

Annual PV yield2.4 MWhper year
PV revenue$381per year
Cell-temp derate−10.8%cells ≈ 30°C above STC (insulated rear)

Trade-offs & engineering notes

Heat build-up — laminated to VIG, solar cells cannot shed heat rearward, so they run warmer and lose output (−0.2 to −0.45% per °C). The derate above is already applied.

Daylight & winter gain — the PV layer reduces visible light transmittance (20% VLT selected) and blocks some winter passive solar gain; the cooling side of the model already reflects the lower solar factor.

Thermal stress — a sustained temperature difference between the outer PV laminate and the inner lite is a known stress case for vacuum glazing. Request our test data on this before specifying solar glass on VIG.

Combined return

Total annual savings$796thermal + PV
Simple payback45.8 yrLong — consider higher-efficiency module or better orientation
VIG investment$9,000warm-edge premium
BIPV investment$27,500module premium
Total investment$36,500VIG + BIPV
NPV (10 yr)−$29,680at 5.0% discount
NPV (15 yr)−$26,839at 5.0% discount
NPV (25 yr)−$22,088full analysis period

Carbon reduction

Thermal CO₂ avoided1.4 t CO₂per year
PV CO₂ avoided918 kg CO₂per year
Total annual CO₂2.3 t CO₂per year combined
Lifetime CO₂ (25 yr)57.5 t CO₂total avoided

Compliance indicators

✓ASHRAE 90.1-2022 §5.5✓LEED v4.1 EA Enhanced—EN 50583 BIPV—EPBD nZEB

✓ / ✗ indicates whether entered U-values meet the threshold — not certified compliance. Formal compliance requires NFRC 100/500 (US) or EN 673 / EN ISO 10077 (EU) certified test reports and project-specific engineering review. VIG U-values are pre-certification estimates.

Download BIPV ROI Report (PDF)
Trade accounts can save this configuration to their dashboard.Sign in to save

Assumptions: Discount rate 5% · Energy escalation 2.5%/yr · $0.16/kWh · Module CIGS · Cooling included